SYMAP® Compact
- GENSET Protection and Control (EC0,EC1, EC2, EC3 and EC4)
|
|
| Code Identifier. |
Code No. |
SHORT DESCRIPTION |
+EC4 |
| 1 |
+EC4 |
Application:
"GENSET Protection and control"
Standard equipment
Dimensions:
Housing dimensions (WxHxD): (210x250x87)mm
Dimensions front plate (WxHxD): (210x250x4)mm
Cutout (WxH): (192x232)mm
Front plate:
"Stucke"-Logo (Design)
LED indication: 3 status-LEDs (Trip: red/Alarm: red-flashing/System: red/green)
8 LED indications (parametrizable, red/green)
Membrane keyboard: 6 x memebrane keys (menu navigation/parameter setting/Reset/password/ON/OFF)
Display:
Graphical LC-Display/Touchscreen (320x240 pixel)
Current measurement:
1 x CT1 (3-phase:0-25 x In); 1 x CT-GND1 (1-phase:measuring range optional)
Voltage measurement:
1 x PT1 (3-phasig: 50 – 130 V / 200 – 690 V); 1 x PT2 (3-phasig: 50 – 130 V / 200 – 690 V); 1 x PT3 (3-phasig: 50 – 130 V / 200 – 690 V);
1 x PT-GND1 (1-phasig: 50 – 130 V / 200 – 690 V)
Binary I/O:
Binary inputs: 19 pcs. (10 - 230V AC/DC; rooted)
Binary outputs: 12 pcs. (potential-free contacts)
Communication interfaces:
1 x mini-USB, on the side of the housing (parameter setting)
1 x CANBUS1/CANBUS2 (external communication)
1 x CANBUS 0 (Extended boards)
1 x RS422/RS485 (Modubus RTU; half- and full-duplex)
1 x USB interface (front plate; parameter setting)
Control and interlocking: Control function: 5 switching devices;
Field interlocking: 8 switching devices
Gen-Set control functions:
Matching device (ANSI 15)
Powermanagement (Start/Stop)
Load sharing
Frquency controller
Power factor controller (cos phi)
Big concumer request (BCR)
Mains failure
Diesel control
Overspeed (ANSI 12)
Start phase
Stop phase (ANSI 5)
Preferential trip limits/Abnormal BUS condition
Additional limts
Protective functions:
ANSI: 24, 25, 25A, 27, 27Q, 27T, 32, 40, 46, 47, 49, 50, 50G, 50BF, 51, 51G, 51/46VR, 59G, 60L, 60FL, 67, 67G, 74TC, 78, 81, 81R 86, 95i, SOTF
|
S |
| |
|
|
|
| Code Identifier. |
Code No. |
Secondary rated current CT1 |
+EC4 |
| 2 |
CT11 |
CT1: 1 A secondary, rated current (0-25×In) |
O |
| 2 |
CT12 |
CT1: 5 A secondary, rated current (0-25×In) |
O |
| 2 |
CT13 |
CT1-MP: 1 A secondary, rated current (0-25×In) |
O |
| 2 |
CT14 |
CT1-MP: 5 A secondary, rated current (0-25×In) |
O |
| Code Identifier. |
Code No. |
Secondary rated current CT2 |
+EC4 |
| 3 |
CT10 |
without |
S |
| 3 |
CT11 |
CT2: 1 A secondary, rated current (0-25×In), |
O |
| 3 |
CT12 |
CT2: 5 A secondary, rated current (0-25×In), |
O |
| Code Identifier. |
Code No. |
Secondary rated current CT-GND1 |
+EC4 |
| 4 |
CTG1 |
CT-GND1: 1 A secondary, rated current (0-25×In) |
O |
| 4 |
CTG2 |
CT-GND1: 5 A secondary, rated current (0-25×In) |
O |
| 4 |
CTG3 |
CT-GND1: 1-20mA, secondary, rated current |
O |
| 4 |
CTG4 |
CT-GND1: 20-100mA, secondary, rated current |
O |
| Code Identifier. |
Code No. |
Power supply - device |
+EC4 |
| 5 |
L |
12-36 V DC |
O |
| 5 |
M |
36-72 V DC |
O |
| 5 |
H |
110-230 V AC; 110-300 V DC |
O |
| Code Identifier. |
Code No. |
Communication - Basic |
+EC4 |
| 6 |
KB0 |
without (Standard) |
O |
| 6 |
KB1 |
Modbus RTU; RS422/RS485 (half- and full-duplex) |
O |
| Code Identifier. |
Code No. |
Communication - Interfaces |
+EC4 |
| 7 |
KS0 |
without (Standard) |
O |
| 7 |
KS2 |
USB-A at front plate |
O |
| 7 |
KS4 |
FO; Line diff. protection (2km; POF 2,5 (ST plug); Multimode 860 nm; diameter 65/125 um) |
O |
| 7 |
KS5 |
FO; Line diff. protection (20km; POF 2,5 (ST plug); Monomode 1300 nm; diameter 9/125 um) |
O |
| 7 |
KS6 |
RS422 (full-duplex, length of line: 300m); Line diff. protection |
O |
| Code Identifier. |
Code No. |
Communication - SCADA/Automation systems |
+EC4 |
| 8 |
KL0 |
without (Standard) |
S |
| 8 |
KL1 |
Profibus DP ; RS485: D-SUB9 |
O |
| 8 |
KL2 |
Profibus DP; FO |
O |
| 8 |
KL3 |
IEC 60870-5-103; RS 485 |
O |
| 8 |
KL4 |
IEC 60870-5-103; FO |
O |
8 |
KL5 |
IEC 61850; RJ45 (Ethernet) |
O |
8 |
KL6 |
IEC 61850; FO (star-topology) |
O |
8 |
KL7 |
Modbus RTU; RJ45 (Ethernet) |
O |
| Code Identifier. |
Code No. |
Recorder unit |
+EC4 |
| 9 |
R0 |
without (Standard) |
S |
| 9 |
R1 |
with recording unit |
O |
| Code Identifier. |
Code No. |
Additional protective function 1 |
+EC4 |
| 10 |
P0 |
without (Standard) |
S |
| 10 |
P2 |
ANSI 87: Current differential protection |
O |
| Code Identifier. |
Code No. |
Key switches |
+EC4 |
| 11 |
S0 |
1 x USB-Stick, coded (Standard) |
S |
| 11 |
S1 |
1 key switch |
O |
| 11 |
S2 |
2 key switch |
O |
| Code Identifier. |
Code No. |
Front plate (Design) |
+EC4 |
| 12 |
S |
"Stucke" (Standard) |
S |
| 12 |
C |
Customer-specific model; on request (please indicate) |
O |
|
|
|